RPC.STATD(8) BSD System Manager's Manual RPC.STATD(8) NAME rpc.statd — host status monitoring daemon SYNOPSIS rpc.statd [-d] [-h bindip] [-p port] DESCRIPTION The rpc.statd utility is a daemon which co-operates with rpc.statd dae‐ mons on other hosts to provide a status monitoring service. The daemon accepts requests from programs running on the local host (typically, rpc.lockd(8), the NFS file locking daemon) to monitor the status of spec‐ ified hosts. If a monitored host crashes and restarts, the remote daemon will notify the local daemon, which in turn will notify the local pro‐ gram(s) which requested the monitoring service. Conversely, if this host crashes and re-starts, when the rpc.statd re-starts, it will notify all of the hosts which were being monitored at the time of the crash. The following option is available: -d Cause debugging information to be written to syslog, recording all RPC transactions to the daemon. These messages are logged with level LOG_DEBUG and facility LOG_DAEMON. Error conditions are logged irrespective of this option, using level LOG_ERR. -h bindip Specify specific IP addresses to bind to. This option may be specified multiple times. If no -h option is specified, rpc.statd will bind to INADDR_ANY. Note that when specifying IP addresses with -h, rpc.statd will automatically add 127.0.0.1 and if IPv6 is enabled, ::1 to the list. -p The -p option allow to force the daemon to bind to the specified port, for both AF_INET and AF_INET6 address families. The rpc.statd utility must NOT be invoked by inetd(8) because the proto‐ col assumes that the daemon will run from system start time. Instead, it should be run from rc(8) after the network has been started. FILES /var/db/statd.status non-volatile record of currently moni‐ tored hosts. /usr/include/rpcsvc/sm_inter.x RPC protocol specification used by local applications to register monitoring requests. SEE ALSO syslog(3), rc(8), rpc.lockd(8) STANDARDS The implementation is based on the specification in X/Open CAE Specifica‐ tion C218, "Protocols for X/Open PC Interworking: XNFS, Issue 4", ISBN 1 872630 66 9 BUGS There is no means for the daemon to tell when a monitored host has disap‐ peared permanently (e.g. catastrophic hardware failure), as opposed to transient failure of the host or an intermediate router. At present, it will re-try notification attempts at frequent intervals for 10 minutes, then hourly, and finally gives up after 24 hours. The protocol requires that symmetric monitor requests are made to both the local and remote daemon in order to establish a monitored relation‐ ship. This is convenient for the NFS locking protocol, but probably reduces the usefulness of the monitoring system for other applications. The current implementation uses more than 1Kbyte per monitored host in the status file (and also in VM). This may be inefficient for NFS servers with large numbers of clients. BSD November 1, 2007 BSD